General

FortaFire Cavity Fire Barriers, why, where, testing and facts

Why cavity fire barriers 

If not contained, a fire will spread rapidly, usually upwards and out into roof void areas, it will quickly develop and spread destroying the whole building. By utilising flexible fire barriers to compartmentate the building, especially the roof voids, into smaller more manageable areas,areas,  you can reduce the risk, by containing the fire for a specified amount of time.

FortaFire flexible fire barriers are specifically used for the purpose of containing fire in a specific area for a given amount of time. They can be used in Commercial or Domestic buildings, and can be installed vertically or horizontally to provide compartmentation, to give occupants of the building sufficient time to escape. and the emergency services to do their job safely, whilst also reducing the risk to passing personnel and nearby buildings.


Where to use FortaFire cavity fire barriers

Fully Certified to:
BS EN 1364-1 - 120/90
BS EN 1364-1 - 120/60

Fully tested to UL263 - 120/58

FortaFire flexbile fire barriers are commonly used for:
  • Compartmentation of Roof Voids
  • Fire-Rated Ceilings upgrade
  • Under Mezzanines
  • Control zones
  • Create a Fire Wall
  • Extend Fire Walls to roof
  • Party Wall to stop fire break-out
  • Across Corridors
  • Along escape routes
  • Stairwells
  • Risers
  • Segregate loft space                 (example Social Housing)
  • Loft conversions
  • Movement joints
  • To provide a plenum area

Testing

It is of absolute importance that the product to be specified for Compartmentation purposes, is a fully tested product, tested to the correct test criteria and meets the correct specification requirement.


The FortaFire range of products have been subjected to more arduous testing than the standard BS.476 Part 20:22 fire test requirements.


Firstly the Fortafire products were tested on a much larger scale than is currently undertaken in the UK for flexible fire barriers, the fire barrier was tested on a full 5m x 5m test rig, compared to the 3m x 3m rig utilised in the UK.


Secondly the tests were conducted at UL, (Underwriters Laboratory) which is the top-rated safety certification in the world, because their testing process is more rigorous and comprehensive than other Certifications.


Thirdly the ForatFire products were also tested against the BS EN standard, which again is a far more onerous fire test than the test to BS.476 Part 20:22, particularly apparent in the early stages of the test. 


Why?


Simply because TBA Protective Solutions (TBAPS) wanted to ensure that we could be confident in the promotion of specifications and installations of the FortaFire range, not just in the UK but throughout the World, and the peace of mind that comes with extremely successful test results under rigorous selection and testing procedures.

Facts

Fire is still one of the most catastrophic of killers, in England alone with a population of 55.5 million, in the period 2017/2018 the following numbers were reported:**


  • 654,877 incidents,3% up on previous year
  • 167,150 primary fires, up 1% on previous year
  • 30,744 were in dwellings (housing)
  • 15,577 were in "other" building types
  • 801 fires in purpose built high rise flats
  • 6% high rise fires spread beyond the room of origin
  • an increase in deaths, as a direct result of fire
  • smoke inhalation major factor in fire deaths


To reduce risk, during a fire, Building Regulations deem that large areas in buildings, for example roof voids or escape routes should be compartmentalised, by sub-dividing a building into fire compartments, utilising fire barriers, which create smaller areas that are more manageable areas of risk. Likewise any penetrations (usually services) that pass through these fire-rated components must also be fire stopped correctly.


The purpose of Fire Compartmentation is primarily to:-


  • Compartmentalise large spaces into manageable areas of risk
  • Prevent and contain the spread of fire, smoke and toxic gases
  • Allow occupants sufficient time to evacuate safely, and the emergency services to enter
  • Reduce damage to property and contents from fire and smoke



**UK Government Home Office Statistical Bulletin 2018


FortaFire - Further information

If you would like any information, Technical support or just a chat about the FortaFire range of products please either give us call on Tel: 01706 577480 (direct line) or email us at info@fortafire.com
or use the contact form on this site

 We would love to hear from you
Contact us
Share by: